Grove - CO2 Sensor (Winsen MH-Z16)

An NDIR carbon-dioxide sensor on a Grove UART cable. Tells you when a room needs fresh air.

Not yet testedLow confidence

From $97.90

Say it to PAL

“Tell me when the room needs fresh air.”

The code PAL writes

p.onSensorChange('winsen-mh-z16', 'co2', (ppm) => {
  if (ppm > 1000) p.log(`CO2 ${ppm} ppm - open a window`);
});

When to pick it

Use for ventilation decisions and indoor air quality when you already own the Grove CO2 sensor.

Good to know

  • The heater needs a 5 V supply; the data lines are 3.3 V logic. Power it from 5 V, never from a 3.3 V-only Grove port.
  • Readings in the first 3 minutes after power-up (its preheat) can be off.
  • Cross TX/RX: board TX -> sensor RX, board RX <- sensor TX. No reply at all usually means they are not crossed or the sensor has no 5 V.

About it

Seeed's Grove - CO2 Sensor carries a Winsen MH-Z16 NDIR sensor and answers over UART at 9600 8N1 with a 9-byte checksummed frame. Range 0-2000 ppm. The heater needs 4.5-6 V; allow 3 minutes of preheat after power-up.

Where to buy

Facts

Tested

Not yet testedLow confidence

It is in our catalog, but nobody has checked it on a real board. It may not work yet. Its driver is written, but it has not been tested on hardware yet.

Chip

MH-Z16

Its sensor is the Winsen MH-Z16.

MH-Z16 datasheet

Free to reuse

Every fact here is open data under CC BY 4.0. Copy it into your own docs or code, and credit Palpable. Download it